Water-driven operation
Flowing water powers the mechanical movement, without an external electrical supply for basic operation.
Self Oscillating Device shown. Monitor selection, connection sizes and the final assembly are confirmed with your quotation.
FROZENFIRE · OSCILLATING DEVICES
Water-powered movement. A sweeping discharge.
An automatic mechanical oscillating device for fixed fire monitors, using the energy of flowing water to produce side-to-side movement for water and foam-solution applications.
PRODUCT OVERVIEW
The Self Oscillating Device introduces a controlled sweeping movement to a fixed fire-monitor installation. Pressurised water activates an internal mechanical mechanism, moving the discharge assembly from side to side across a defined area.
Its water-driven operating principle requires no external electrical supply for basic oscillation. The flanged body connects into the fire-water arrangement, with the monitor, connections and required sweep selected for the application. The device is specified for water or foam-solution service.
Flowing water powers the mechanical movement, without an external electrical supply for basic operation.
Side-to-side movement distributes the discharge across the selected area rather than a single stationary direction.
Vertical mounting with flanged inlet and outlet connections suits integration with a fixed fire-monitor arrangement.
TECHNICAL SPECIFICATIONS
Specifications from page 3 of the Self Oscillating Device catalogue.
Selected to suit the fire monitor and its installation.
| Parameter | Specification |
|---|---|
| Product | Oscillating Device |
| Brand | FROZENFIRE |
| Application | Automatic oscillation of a fire monitor |
| Type | Mechanical / automatic oscillating device |
| Installation | Flanged |
| Mounting | Vertical |
| Body material | Stainless steel |
| Swivel joint | Gun metal |
| Inlet & outlet connections | Flanged |
| Nominal size | 3″ / 4″, as per fire-monitor requirement |
| Working pressure | Up to 12 bar* |
| Test pressure | Up to 21 bar* |
| Oscillation | Automatic side-to-side movement |
| Oscillation range | Adjustable as required* |
| Movement control | Mechanical |
| Operating medium | Water / foam solution |
| Surface finish | Red industrial protective coating |
| Operating temperature | As per system / application requirements |
| Maintenance | Low-maintenance mechanical design; periodic inspection required |
| Installation environment | Industrial / outdoor fire-protection systems |
* Final working pressure, test pressure and oscillation range must be confirmed for the selected model, connection size and design configuration. Coverage, flow rate and operating temperature are application dependent; no fixed values are specified in this catalogue.
CONSTRUCTION
A mechanical arrangement of body, swivel, linkage and water-flow components.
Heavy-duty housing with a stainless-steel body and red industrial protective coating.
Flanged water inlet and outlet with a gun-metal swivel joint.
Internal water-flow mechanism, operating lever/linkage, pivots and spring-loaded components.
WORKING PRINCIPLE
Continuous sweeping action is produced by the hydraulic force of the flowing water.
Pressurised water from the fixed fire-water supply enters the device.
Hydraulic force activates the internal mechanical assembly and its linkage.
The attached discharge assembly moves from side to side across the selected coverage area.
Check that the device, piping, flanges and supporting structure are properly installed and securely fastened. Open the fire-water supply gradually and verify smooth oscillating movement.
Read operation & maintenanceCONFIGURATION & ENQUIRIES
Coverage range, oscillation angle, flow and operating pressure depend on the selected model and system design.
Identify the fixed monitor, vertical mounting arrangement and supporting structure. Share the assembly or connection drawing for review.
Specify the required 3″ or 4″ flanged inlet/outlet arrangement and mating flange details.
Provide available pressure, required flow, intended water or foam-solution service and required oscillation angle / coverage area.
Include quantity, application, delivery location and any required drawings or documentation.
APPLICATIONS
Application areas identified in the catalogue. Select the device and fire-monitor arrangement for the required coverage.
INSPECTION & MAINTENANCE
Periodic checks from the supplied catalogue. Include the device in the site’s fire-protection maintenance programme.
DOCUMENTS & SUPPORT
Download the original catalogue, print this page or request details for the selected installation.
Original Frozenfire catalogue
Overview, features, working principle, construction, applications, technical data and operation & maintenance.
Download catalogue Open PDFProduct and project enquiries
Share the monitor arrangement, connection sizes, available water pressure, required flow and sweep. Our team can review the configuration and supporting documentation.