FIRE FIGHTING EQUIPMENT MANUFACTURER
Ahmedabad, Indiainfo@frozenfire.in

Product configuration and finish shown. Confirm the supplied material, inlet connection and colour with your quotation.

FROZENFIRE · MEDIUM EXPANSION

MEFG 1100 LPM Foam Generator

Medium expansion. 1,100 LPM nominal flow.

An air-aspirating medium expansion foam generator with a catalogue nominal flow of 1100 LPM at 3.5 kg/cm² branch-inlet pressure, for fixed and semi-fixed foam systems.

Medium expansionAir aspirationFixed / semi-fixed
Discuss your requirement +91 7878 717 818
Nominal flow
1100LPM*
Discharge range
3 mat specified inlet pressure*
Expansion
1:40standard AFFF*
Length
920mm

* Flow and range at 3.5 kg/cm² branch-inlet pressure; expansion using standard AFFF compound, as tabulated in the catalogue.

PRODUCT OVERVIEW

Foam solution.
Air. Controlled discharge.

The MEFG uses air aspiration to turn a proportioned foam solution into a medium-expansion foam discharge. Solution passes through a calibrated nozzle, inducing atmospheric air before moving through the stainless-steel foam-generating screen.

A matching inline inductor or suitable proportioning system supplies the required foam solution. The generator is intended for an engineered fixed or semi-fixed arrangement, with concentrate selection, inlet pressure and discharge clearance matched to the protected hazard.

01

Air-aspirating operation

The solution stream draws air through the inlet openings without moving mechanical parts.

02

Foam-generating screen

A stainless-steel mesh forms the aspirated solution into medium-expansion foam.

03

Matched proportioning

A compatible inline inductor or proportioning system supplies the selected foam concentration.

TECHNICAL SPECIFICATIONS

The model.
The materials.
The operating conditions.

Model-specific performance and typical range construction, with catalogue conditions retained.

SELECTED MODELMEFG 1100

Medium expansion foam generator

Download catalogue
MEFG 1100 LPM Foam Generator technical specifications
ParameterSpecification
ModelMEFG 1100
TypeMedium expansion foam generator
Nominal flow1100 LPM at 3.5 kg/cm² branch-inlet pressure
Discharge range3 m at 3.5 kg/cm² branch-inlet pressure
Model expansion ratio1:40 using standard AFFF compound
Length920 mm
Approximate weight18.0 — unit not stated in catalogue; confirm before specification
Typical operating pressure3.5–7 bar — general range data
Body materialStainless steel — typical specification; aluminium alloy listed as a range option
Foam-generating screenStainless steel
Inlet connectionANSI Class 150 flanged end; threaded / flanged alternatives listed
Inline inductorStainless steel, matching the selected duty
Inline inductor size3″ / 4″ — range options; confirm for selected model
FinishEpoxy red / natural in the technical table; final finish as selected
InstallationFixed / semi-fixed
Operating mediumFoam solution
Concentrate typesAFFF / AR-AFFF / protein / fluoroprotein, subject to compatibility

Flow and range are tabulated at 3.5 kg/cm² pressure at the branch inlet. Expansion of 1:40 is specified using standard AFFF compound. These model conditions are distinct from the general 3.5–7 bar operating-pressure range.

Expansion data & concentrate selection

The model performance table specifies 1:40 with standard AFFF. General catalogue text also quotes 1:35–1:50 and 1:40–1:200. Confirm the achievable expansion with the selected concentrate and operating conditions.

CONSTRUCTION

The assembly
behind the discharge.

Component materials and arrangement from the selected product catalogue.

01

Body & screen

Stainless-steel body and foam-generating screen in the typical technical specification. The construction section also lists an aluminium-alloy body option; confirm the selected material.

02

Nozzle & air path

Calibrated solution nozzle, air-induction chamber, inlet openings and foam discharge outlet.

03

Connections & finish

The catalogue lists an ANSI Class 150 flanged inlet and threaded / flanged alternatives. Finish and mating connection follow the selected assembly.

OPERATION

Prepare the system.
Establish the foam discharge.

Catalogue guidance used with the approved fire-protection system procedures and selected foam concentrate.

  1. 01

    Prepare the installation

    Follow the approved system layout, flush supply piping before installation and keep air inlets and the foam discharge path unobstructed.

  2. 02

    Supply proportioned solution

    The fire-protection system supplies the selected water and foam-concentrate mixture when activated.

  3. 03

    Induce air & form foam

    Solution passes through the calibrated nozzle, induces atmospheric air and moves through the foam-generating mesh.

  4. 04

    Discharge & shut down

    Foam discharges into the selected hazard area. Control operation and shutdown according to the approved system procedure.

CONFIGURATION & ENQUIRIES

Specify the complete
operating arrangement.

Confirm the generator, proportioning, connections and installation together.

01

Foam concentrate

The catalogue lists AFFF, AR-AFFF, protein and fluoroprotein concentrates. Confirm the specific concentrate, proportioning percentage and hazard compatibility.

02

Inductor & supply

Confirm the required flow, available inlet pressure and matching inductor. The range lists stainless-steel inductors in 3″ / 4″ sizes without assigning a size to each MEFG model.

03

Inlet & installation

Specify mating flange drilling or threaded connection, mounting orientation, body material, finish and available air/discharge clearance.

Discuss a configuration

Share the MEFG model, required duty, foam concentrate, proportioning arrangement, inlet connection, mounting details, quantity and delivery location.

APPLICATIONS

Selected for the hazard.
Integrated with the system.

Application areas identified in the catalogue. Final suitability depends on the hazard, concentrate and approved system design.

  • 01Aircraft hangars
  • 02Oil & gas installations
  • 03Chemical plants & refineries
  • 04Warehouses
  • 05Cable tunnels
  • 06Transformer rooms
  • 07Pump houses
  • 08Marine engine rooms
  • 09Fuel storage & loading bays
  • 10LPG / LNG installations
  • 11Paint & solvent storage
  • 12Industrial process areas

INSPECTION & MAINTENANCE

Keep the air path clear.
Maintain the assembly.

Use the catalogue inspection intervals within the facility’s approved maintenance programme. Confirm the concentrate manufacturer’s cleaning instructions.

01Monthly inspection
  • Inspect the body for physical damage, corrosion and coating deterioration.
  • Keep air openings clear and check pipe connections for leakage.
02Quarterly maintenance
  • Inspect the screen for dirt, corrosion or blockage; clean with water and a soft brush.
  • Check the inlet nozzle, mounting brackets and supports.
03Annual checks
  • Carry out an operational discharge test where permitted and verify expansion and discharge performance.
  • Inspect seals and connections; replace damaged mesh or worn components and confirm compatibility with the concentrate in use.
04Cleaning & protection
  • Do not paint or obstruct the air openings or use metal tools that could damage the screen.
  • Flush after testing when recommended by the foam-concentrate manufacturer. Protect the equipment from dust, insects and debris.

DOCUMENTS & SUPPORT

The original catalogue.
Details for your project.

Download product literature, print this page or request supporting information for the selected configuration.

Medium Expansion Foam Generator

Original Frozenfire catalogue

MEFG construction, model performance data, typical specifications, installation and maintenance.

5 pages · Rev. 07/26 · 394 KBDownload catalogue Open PDF

Technical & project support

Product and project enquiries

Share the MEFG model, required duty, foam concentrate, proportioning arrangement, inlet connection, mounting details, quantity and delivery location.

Request technical details

MEFG 1100 LPM Foam Generator

Frozenfire MEFG 1100 LPM foam generator with yellow cylindrical housing, carrying handles, solution piping and flanged inlet on a white background