Controlled spray pattern
A precision-machined orifice and stainless-steel deflector distribute the incoming water.
The photograph shows a representative nozzle. The catalogue specifies a brass body and stainless-steel deflector; confirm the supplied finish and configuration.
FROZENFIRE · SPRINKLERS
Medium velocity spray. Defined surface coverage.
A fixed water spray nozzle for cooling, exposure protection and industrial fire-control applications. Select the spray angle, connection and hydraulic characteristics for the protected equipment.
PRODUCT OVERVIEW
The Frozenfire MV Spray Nozzle distributes water over equipment and exposed surfaces in fixed water spray installations. Its internal orifice and deflector produce a medium velocity spray pattern for cooling and exposure protection.
Spray angle, discharge coefficient, connection size, spacing and orientation are selected as part of the approved hydraulic design. Horizontal, vertical and inclined installation are listed in the catalogue.
The nozzle receives water when the deluge or water spray system is activated. The catalogue lists several angle and connection options; specific flow, K-factor and pressure data must be confirmed for the selected model.
A precision-machined orifice and stainless-steel deflector distribute the incoming water.
65°, 80°, 95°, 110° and 120° are listed. Select the model and nozzle spacing for the required coverage.
Horizontal, vertical or inclined orientation according to the approved system drawings.
TECHNICAL SPECIFICATIONS
Review the catalogue values and confirm the selected configuration against your project requirements.
Download catalogue| Parameter | Catalogue specification |
|---|---|
| Product type | Medium velocity water spray nozzle |
| Body material | Brass |
| Deflector | Stainless steel |
| Orifice | Precision machined |
| Connection | BSPT / NPT threaded |
| Connection sizes | ½″, ¾″ and 1″ |
| Spray angle options | 65°, 80°, 95°, 110° and 120°; selected by model |
| Installation | Horizontal, vertical or inclined |
| Operating medium | Clean water |
| Finish | Catalogue wording: Natural Brass / SS Polished; confirm the finish of the selected nozzle |
| Application | Fixed water spray fire-protection system |
| K-factor / flow | Model-specific data required; numeric values are not supplied in this catalogue |
| Working / test pressure | Confirm model-specific ratings; numeric values are not supplied in this catalogue |
Spray angle and connection size do not establish flow or coverage on their own. Request the selected model’s K-factor and pressure data for the approved hydraulic design.
CONSTRUCTION
Product construction and connection options from the catalogue.
Threaded BSPT / NPT inlet in the listed connection sizes.
Machined discharge passage; its geometry must not be enlarged or damaged during cleaning.
Shapes the water distribution into the model’s specified spray angle.
WORKING PRINCIPLE
Understand the discharge device in the context of the complete fire-protection system.
The detection and deluge arrangement supplies water to the fixed piping network.
Pressurised water passes through the orifice and across the deflector.
The selected spray pattern applies water across the target surface for cooling and exposure protection.
The system controls water supply and shutdown. Coverage must follow the approved nozzle selection, spacing and orientation.
CONFIGURATION & ENQUIRIES
Share the installation and project requirements with our team.
Request the selected K-factor, discharge data and pressure rating. Match these to the approved hydraulic calculation.
Choose the required angle, connection and orientation. Share drawings showing protected equipment and nozzle positions.
Flush the pipework before fitting. Use compatible thread sealant and verify the model, angle, spacing and orientation before commissioning.
Share the required angle, connection, installation drawing, model-specific hydraulic data, quantity and delivery location.
OPERATION
Catalogue guidance for use within the approved system operating procedure.
Verify the approved drawing, unobstructed spray openings, correct orientation and adequate water supply.
The deluge or water spray system supplies water. The nozzle distributes it through the orifice and deflector.
Follow the system operating procedure for shutdown. Depressurise before inspection, cleaning or replacement.
APPLICATIONS
Application areas identified in the product catalogue; select the complete arrangement for the protected hazard.
INSPECTION & MAINTENANCE
Depressurise before maintenance. Do not paint or obstruct the nozzle. Use the approved replacement components and the facility’s maintenance procedure.
DOCUMENTS & SUPPORT
Download the original catalogue or request model-specific technical documentation.
Original Frozenfire catalogue
Product information, specifications, applications, operation and maintenance.
Download catalogue Open PDFProduct and project enquiries
Share the required angle, connection, installation drawing, model-specific hydraulic data, quantity and delivery location.
Request technical details