FIRE FIGHTING EQUIPMENT MANUFACTURER
Ahmedabad, Indiainfo@frozenfire.in

Photographed assembly. Select the model, materials, connections and accessories to suit your installation.

FROZENFIRE · WM SERIES

Stand Post Type Water Monitor

Manual direction. A fixed installation.

A manually operated stand post water monitor with a flanged base, threaded nozzle connection, independent directional controls and integrated drain valve.

Manual controlFlanged mountingWM series
Discuss your requirement +91 7878 717 818
Typical flow range
1000–3500 LPM
Typical pressure
7–16 bar
Rotation
Approx. 360°
Typical elevation
−45° to +90°

Water Monitor catalogue values vary by model. Rotation may be continuous or limited according to the selected design.

PRODUCT OVERVIEW

Water delivery.
Manual control.

The Frozenfire stand post water monitor provides manual control of a water stream from a fixed flanged installation. The vertical riser and curved outlet arm carry water from the fire-water line to the selected monitor nozzle.

Separate horizontal and elevation controls position the discharge direction. Locking levers secure the selected position, while the drain ball valve supports drainage after testing or use.

The WM series catalogue lists four sizes from 50 to 100 mm. Choose the model, nozzle bore, body material and connection details together for the required water supply and installation.

01

Independent aiming

Manual horizontal rotation and vertical elevation controls.

02

Nozzle connection

Threaded outlet for the selected monitor nozzle.

03

Fixed base and drainage

Flanged mounting and an integrated drain ball valve.

TYPICAL TECHNICAL SPECIFICATIONS

Materials.
Connections. Control.

Typical specifications from the Stand Post Type Water Monitor catalogue, page 4, with WM model options shown separately below.

Download catalogue
Stand Post Type Water Monitor typical specifications
ParameterDetail
Product typeStand post type water monitor
Standard listed in catalogueIS 8442, Type-I
OperationManual horizontal and vertical movement
Body materialCarbon steel / stainless steel
Swivel joint materialStainless steel / gun metal
Nozzle materialAluminium / stainless steel / gun metal
Nozzle bore options26 / 32 / 38 / 45 mm
FinishHot dip galvanizing and red epoxy / polyester coating
Inlet connectionFlanged
Outlet connectionThreaded
Typical flow capacityApproximately 1000–3500 LPM, model dependent
Typical operating pressure7–16 bar (100–230 psi), model dependent
Horizontal rotationApproximately 360°; continuous or limited, depending on design
Typical elevation range−45° to +90°, model dependent
MediaWater
Drain valveIntegrated ball valve
MountingFixed flange base

Select the required material and connection options with your quotation. The listed standard follows the catalogue; request applicable documentation for the selected model.

MODEL RANGE & PERFORMANCE

Model by model.
Ready to specify.

Four WM models and their water-jet figures, as listed on page 5 of the Water Monitor catalogue.

Scroll sideways to see the full table.

Stand Post Type Water Monitor catalogue model references
Model numberSize (mm)Flow (LPM)Water jet (m)
FIL/50/WM50100045
FIL/63/WM63175055
FIL/75/WM75258060
FIL/100/WM100350065

These are catalogue model references. Throw test conditions are not specified in the table; confirm the selected model, nozzle and supply conditions with your quotation.

CONSTRUCTION & COMPONENTS

From the flanged base
to the nozzle.

Component and material options for the complete monitor assembly.

Stand Post Type Water Monitor construction
ParameterDetail
Flanged baseBolt-hole mounting flange for connection to the fire-water piping
Vertical riserSupports the swivel assembly and carries the water supply
Curved outlet armDirects the waterway toward the nozzle outlet
Threaded outletConnection for the selected water, jet/fog, foam or long-range monitor nozzle
Operating handleManual left / right directional control
Elevation controlSide control for raising, lowering and holding the discharge angle
Locking mechanismsSeparate controls for horizontal and vertical positioning
Drain ball valveDrains residual or trapped water from the monitor

WORKING PRINCIPLE

Supply.
Direction. Discharge.

How the monitor assembly carries and directs the firefighting media.

01

Water inlet

Water enters through the flanged base from the fire-water pipeline.

02

Waterway and nozzle

The supply passes through the vertical riser and curved outlet arm to the threaded nozzle connection.

03

Direction and position

Manual controls set azimuth and elevation, with locking handles securing the selected discharge direction.

APPLICATIONS

For industrial
fire protection.

Application areas described in the corresponding product catalogue.

  • 01Oil and gas facilities
  • 02Tank farms and refineries
  • 03Chemical and industrial processing plants
  • 04Power stations
  • 05Aircraft hangars
  • 06Warehouses
  • 07Marine and LNG / LPG terminals
  • 08Fire pump houses

MAINTENANCE

Care for the
complete assembly.

Routine care items listed on page 5 of the Water Monitor catalogue.

  • 01Inspect for corrosion or coating damage
  • 02Lubricate rotating joints
  • 03Check locking mechanisms
  • 04Test smooth movement in both axes
  • 05Verify drain valve operation
  • 06Inspect flange bolts and gaskets
  • 07Carry out periodic flow tests
  • 08Keep nozzle threads clean and undamaged

DOCUMENTS & SUPPORT

Product information.
Ready to reference.

Download the original catalogue, print this page or discuss your selected assembly.

Stand Post Type Water Monitor

Original Frozenfire catalogue

Original five-page catalogue with WM model references, typical specifications, components and maintenance information.

5 pages · Rev. 07/26 · 322 KBDownload catalogue Open PDF

Specify your assembly

Product and project enquiries

Share the model, nozzle type, material, inlet connection, required flow and supply pressure. Include the quantity and delivery requirement.

Request technical details

Stand Post Type Water Monitor

Frozenfire red stand post water monitor with silver jet nozzle, original nameplate, operating handle, locking levers and blue drain valve