Double Headed Stand Post with Pumper Connection

Hose delivery. Fire-appliance connection.

A double-headed hydrant stand post combining hose outlets with a pumper inlet for a compatible fire appliance to supplement the fire-water supply.

Double headedPumper connectionNon-return arrangement
Discuss your requirement +91 7878 717 818
Hose outlets
02double-headed model
Hose outlet size
63 mm2½″ instantaneous
Pumper inlet
100 / 150 mmselected configuration
Installation
Fixedabove ground

PRODUCT OVERVIEW

A fixed outlet.
Ready for connection.

This stand post combines the two hose outlets of a double-headed hydrant with an additional fire-brigade pumper connection. A compatible fire appliance can connect to the inlet to supplement the water supplied to the hydrant system.

The model section specifies a carbon-steel body, stainless-steel valve spindles, renewable bronze seats and a built-in non-return valve arrangement. The inlet size, pumper arrangement and mating coupling are selected for the installation.

01

Hose outlets & pumper inlet

A double-headed hose arrangement with an additional fire-appliance connection.

02

Non-return arrangement

The built-in non-return valve arrangement controls reverse flow through the pumper connection.

03

Serviceable construction

Carbon-steel body, stainless-steel spindles and renewable bronze valve seats.

TECHNICAL SPECIFICATIONS

Construction.
Connections. Duty.

Model features and typical range data from the Fire Hydrant Stand Post catalogue.

HOSE OUTLET SIZE63 mm

Two hose outlets with compatible instantaneous hose connections.

Download catalogue
Double Headed Stand Post with Pumper Connection technical specifications
ParameterSpecification
Product familyFire hydrant stand post
Body materialCarbon steel — as specified in this model’s feature section
Hydrant valve materialStainless steel / gun metal, as selected
Hose outlets2 × 63 mm (2½″) instantaneous
Inlet connectionFlanged; ANSI / IS drilling as selected
Stand post height600 mm typical; customised height available
Working pressureUp to 16 bar — typical range value*
Hydrostatic test pressureUp to 24 bar — typical range value*
OperationManual handwheel
Flow directionStraight through
FinishFire-red epoxy powder coating / epoxy finish as applicable
InstallationFixed, vertical, above ground
Temperature range−10°C to +80°C — typical range value*
Outlet protectionBlank caps with retaining chains
Pumper inlet size100 mm (4″) or 150 mm (6″), as required
Pumper arrangement2-way or 4-way arrangement, subject to the approved assembly
Pumper inlet capStainless steel / gun metal female round-threaded blank cap with chain
Backflow controlBuilt-in non-return valve arrangement
Valve spindleStainless steel
Valve seatRenewable bronze

* These are typical stand-post range specifications. Confirm the final material, height, connections, working pressure, test pressure and temperature limits against the selected configuration. Hydrostatic test pressure is not the operating pressure.

CONFIGURATION & SELECTION

The details that
define your assembly.

Discuss these range options with your enquiry. The final assembly and supplied accessories follow the agreed configuration.

01

Construction & finish

Carbon steel or stainless-steel construction as selected. SS 304 / SS 316 and marine-grade epoxy are optional range configurations; confirm availability for the chosen model.

02

Connections & height

Confirm mating flange size and drilling, required outlet arrangement and installation height. Flanged or threaded inlet options are listed in the range catalogue.

03

Barrel & drainage

Wet-barrel or dry-barrel configurations are available for discussion. An automatic drain valve is an option for the dry-barrel design.

04

Site accessories

Discuss tamper-proof or lockable outlet caps, reflective markings and a pressure-gauge connection. Accessories are supplied according to the agreed configuration.

05

Pumper interface

Confirm the selected 100 mm or 150 mm inlet, fire-brigade coupling, pumper arrangement and non-return valve requirements against the intended fire appliance.

This page presents the double-headed model. The catalogue also lists alternative two- or four-way arrangements. Confirm the final hose outlets, pumper arrangement and inlet size on the approved assembly drawing.

Discuss a configuration

Share the outlet arrangement, body and valve materials, inlet flange details, required height, operating pressure, quantity and delivery location. Include the installation drawing where available.

OPERATION

Connect. Control.
Return to standby.

Catalogue guidance for trained personnel following the applicable hydrant-system procedures.

  1. 01

    Inspect the assembly

    Check the stand post, valves and accessible connections before use. Ensure the operating area and hose route are clear.

  2. 02

    Connect the hose

    Remove the outlet cap and securely connect a compatible hose. Check the coupling engagement and hose arrangement.

  3. 03

    Open gradually

    Operate the handwheel gradually in the indicated opening direction and regulate the water supply for the required duty.

  4. 04

    Close & restore

    Close gradually after use. Confirm that residual pressure has been relieved before disconnecting, replace caps and check for leakage.

Pumper connection

A compatible fire appliance connects to the selected pumper inlet to supplement the fire-water supply. Verify the coupling and non-return arrangement, and follow the approved fire-appliance and site operating procedure.

Avoid sudden valve operation. Secure hose connections before establishing flow and confirm that residual pressure has been relieved before disconnection.

APPLICATIONS

For the selected
fire-water arrangement.

Application areas listed in the product catalogue. Equipment selection remains subject to the site’s hydrant layout and duty.

  • 01Industrial fire-protection systems
  • 02Oil & gas facilities
  • 03Refineries & petrochemical plants
  • 04Chemical industries
  • 05Airports
  • 06Marine & offshore installations
  • 07Warehouses
  • 08Power & steel plants
  • 09Commercial buildings
  • 10Municipal hydrant networks
  • 11Mining industries

INSPECTION & MAINTENANCE

Maintain access.
Check the assembly.

Follow the catalogue schedule together with the site’s maintenance programme. Isolate and depressurise before servicing; never dismantle a pressurised hydrant.

Stand post recommended inspection schedule
ActivityFrequency
Visual inspectionMonthly
Operational checkQuarterly
Flushing & cleaningEvery 6 months
LubricationEvery 6 months or as required
Pressure & flow testAnnually
Complete overhaulEvery 3–5 years or as required
01Monthly inspection
  • Keep access clear; inspect the body, bonnet, outlets and flange for damage, corrosion or coating deterioration.
  • Check caps, chains, visible leakage and the legibility of identification plates.
02Quarterly operational checks
  • Check smooth valve movement and inspect the spindle, gland packing and external fasteners.
  • Clean outlet connections and apply suitable lubricant only where required.
03Half-yearly servicing
  • Flush and clean under the approved site procedure; check unobstructed discharge and sealing after closure.
  • Inspect caps, gaskets and seals, and repair damaged protective coating.
04Annual inspection & testing
  • Inspect mechanical components and replace worn seals or parts as required.
  • Lubricate appropriate moving parts with suitable waterproof grease, avoiding excess.
  • Arrange pressure and flow testing using the approved test procedure and rating, then verify correct operation and closure.
05Pumper connection checks
  • Inspect the inlet coupling, cap, chain and gasket for damage or deterioration.
  • Verify correct non-return valve operation and carry out a connection test with compatible fire-brigade equipment.

DOCUMENTS & SUPPORT

Product literature.
Project-specific details.

Keep the original catalogue to hand, print this page or request information for your selected configuration.

Fire Hydrant Stand Post

Original Frozenfire catalogue

Single headed, double headed and pumper-connection stand posts. Features, typical specifications, operation and maintenance.

8 pages · Rev. 07/26 · 444 KBDownload catalogue Open PDF

Specify your requirement

Product and project enquiries

Share the outlet arrangement, body and valve materials, inlet flange details, required height, operating pressure, quantity and delivery location. Include the installation drawing where available.

Request technical details

Double Headed Stand Post with Pumper Connection

Frozenfire red double-headed stand post with two hose valves and a large capped pumper connection on the front of the body