Hose outlets & pumper inlet
A double-headed hose arrangement with an additional fire-appliance connection.
Catalogue configuration shown. Material, connections, height and accessories are confirmed with your quotation.
FROZENFIRE · FIXED STAND POST
Hose delivery. Fire-appliance connection.
A double-headed hydrant stand post combining hose outlets with a pumper inlet for a compatible fire appliance to supplement the fire-water supply.
PRODUCT OVERVIEW
This stand post combines the two hose outlets of a double-headed hydrant with an additional fire-brigade pumper connection. A compatible fire appliance can connect to the inlet to supplement the water supplied to the hydrant system.
The model section specifies a carbon-steel body, stainless-steel valve spindles, renewable bronze seats and a built-in non-return valve arrangement. The inlet size, pumper arrangement and mating coupling are selected for the installation.
A double-headed hose arrangement with an additional fire-appliance connection.
The built-in non-return valve arrangement controls reverse flow through the pumper connection.
Carbon-steel body, stainless-steel spindles and renewable bronze valve seats.
TECHNICAL SPECIFICATIONS
Model features and typical range data from the Fire Hydrant Stand Post catalogue.
Two hose outlets with compatible instantaneous hose connections.
| Parameter | Specification |
|---|---|
| Product family | Fire hydrant stand post |
| Body material | Carbon steel — as specified in this model’s feature section |
| Hydrant valve material | Stainless steel / gun metal, as selected |
| Hose outlets | 2 × 63 mm (2½″) instantaneous |
| Inlet connection | Flanged; ANSI / IS drilling as selected |
| Stand post height | 600 mm typical; customised height available |
| Working pressure | Up to 16 bar — typical range value* |
| Hydrostatic test pressure | Up to 24 bar — typical range value* |
| Operation | Manual handwheel |
| Flow direction | Straight through |
| Finish | Fire-red epoxy powder coating / epoxy finish as applicable |
| Installation | Fixed, vertical, above ground |
| Temperature range | −10°C to +80°C — typical range value* |
| Outlet protection | Blank caps with retaining chains |
| Pumper inlet size | 100 mm (4″) or 150 mm (6″), as required |
| Pumper arrangement | 2-way or 4-way arrangement, subject to the approved assembly |
| Pumper inlet cap | Stainless steel / gun metal female round-threaded blank cap with chain |
| Backflow control | Built-in non-return valve arrangement |
| Valve spindle | Stainless steel |
| Valve seat | Renewable bronze |
* These are typical stand-post range specifications. Confirm the final material, height, connections, working pressure, test pressure and temperature limits against the selected configuration. Hydrostatic test pressure is not the operating pressure.
CONFIGURATION & SELECTION
Discuss these range options with your enquiry. The final assembly and supplied accessories follow the agreed configuration.
This page presents the double-headed model. The catalogue also lists alternative two- or four-way arrangements. Confirm the final hose outlets, pumper arrangement and inlet size on the approved assembly drawing.
Share the outlet arrangement, body and valve materials, inlet flange details, required height, operating pressure, quantity and delivery location. Include the installation drawing where available.
OPERATION
Catalogue guidance for trained personnel following the applicable hydrant-system procedures.
Check the stand post, valves and accessible connections before use. Ensure the operating area and hose route are clear.
Remove the outlet cap and securely connect a compatible hose. Check the coupling engagement and hose arrangement.
Operate the handwheel gradually in the indicated opening direction and regulate the water supply for the required duty.
Close gradually after use. Confirm that residual pressure has been relieved before disconnecting, replace caps and check for leakage.
A compatible fire appliance connects to the selected pumper inlet to supplement the fire-water supply. Verify the coupling and non-return arrangement, and follow the approved fire-appliance and site operating procedure.
Avoid sudden valve operation. Secure hose connections before establishing flow and confirm that residual pressure has been relieved before disconnection.
APPLICATIONS
Application areas listed in the product catalogue. Equipment selection remains subject to the site’s hydrant layout and duty.
INSPECTION & MAINTENANCE
Follow the catalogue schedule together with the site’s maintenance programme. Isolate and depressurise before servicing; never dismantle a pressurised hydrant.
| Activity | Frequency |
|---|---|
| Visual inspection | Monthly |
| Operational check | Quarterly |
| Flushing & cleaning | Every 6 months |
| Lubrication | Every 6 months or as required |
| Pressure & flow test | Annually |
| Complete overhaul | Every 3–5 years or as required |
DOCUMENTS & SUPPORT
Keep the original catalogue to hand, print this page or request information for your selected configuration.
Original Frozenfire catalogue
Single headed, double headed and pumper-connection stand posts. Features, typical specifications, operation and maintenance.
Download catalogue Open PDFProduct and project enquiries
Share the outlet arrangement, body and valve materials, inlet flange details, required height, operating pressure, quantity and delivery location. Include the installation drawing where available.
Request technical details